Home > Listing Products > Gas Generators > Nitrogen Generators > CELENO Nitrogen Generator
PSA Technology
Reference
CELENO.[Flow rate]/0 (Without compressor) CELENO.[Flow rate]/1 (With compressor)
With 20 L/min, the CELENO Nitrogen range provides a High Purity Nitrogen solution for GC x GC instrument with Cryogen. The generator has very low dew point to work with cryogenic applications without any freezing.
The CELENO is available without or with integrated oil free air compressor using the Energy Saving Technology mode (EST). It is extremely compact and quiet in operation. The generator is controlled using the latest in color touch screen technology to display the process in real time, inlet / outlet pressure, N2 Flow and status of the system with remote access for diagnostic control.
Utilizing Advanced technology PSA of separating Nitrogen and Oxygen to produce high quality Nitrogen gas on demand 24/7.
A constant, uninterrupted gas supply of guaranteed purity
eliminates interruptions of analyses to change cylinders and
reduces the amount of instrument re-calibrations required.
Pure nitrogen gas produced as standard.
Nitrogen produced at low pressure and ambient temperature
removes the need for high pressure cylinders.
Integral oil free air compressor as an option guarantees
continuous gas supply, independent of in house compressed
air supply.
Gas generators can be installed in the laboratory, on or
under a bench, eliminating the need for long gas lines from
cylinders secured elsewhere.
Models | CELENO.20 | |
|---|---|---|
Compressor | 0 (Without) | 1(With) |
GENERALS INFORMATIONS | ||
Max Nitrogen Flow rate | 20 L/min | |
Max Nitrogen outlet pressure | 6 bar (87 psi) | |
Nitrogen purity* | > 99.5% (< 0.5% O2) | |
Nitrogen dewpoint | < -60°C (< -76°F) | |
Particles | 0.01 μ | |
Inlet Air flow required @ 8 bar (116 psi) max | 70 L/min | N /A |
Min Inlet Air quality | ISO8573 – 1:2010 1.4.1 | N/A |
Touch screen | Touch screen (operating parameters, system status, alarms) with LED indicators(Power on/off; ready or errors) | |
Max Relative Humidity | 80% RH @ 25°C (77°F) | |
Temperature range | From 5 – 25°C (41 – 77°F) | |
Max Altitude | 3000 Meters | |
Noise level @ 1M | 25 dB (A) | 52 dB (A) |
Dimensions(W x H x D) | 47.5 x 66.2 x 79 cm(18.7″ x 26″ x 31″) | |
Weight (kg/lbs) | 91 / 200 | 118 / 260 |
Electrical supply | 220 – 240 V ac / 1 ph / 50 – 60 Hz | |
110 – 120 V ac / 1 ph / 50 – 60 Hz | ||
Fuse | 10A | |
CONNECTIONS | ||
Nitrogen outlet | 1/4″ GF | |
COMMUNICATION | ||
USB/PC Control | In series | |
* Factory certified purity with respect to O2 content. Actual purity varies in relation to flow (min. 97% at maximum flowoutput)
Having all the necessary information to successfully complete your project is essential, which is why we are providing you with these documents.
Please feel free to contact us with any questions.