TORNADO Nitrogen Generator

High Flow - PSA Technology - Up to 200.3 NM3/H

Reference

TORNADO.[Flow rate]

The nitrogen generators serie TORNADO offer to you a unique, innovative solution to nitrogen gas supply. A reliable, secure source of nitrogen can be produced from your existing compressed air supply, eliminating the need for liquid nitrogen or high pressure gas cylinders. Conceived for a continuous operation, the TORNADO nitrogen generator can produce flow rates from a few liters per minutes to over NM3/H at purities in oxygen content residual from 10 ppm to 5%. The generator is controlled using the latest in HMI touch screen technology to display the process, pressures, inlet air dewpoint and oxygen levels with continuous monitoringcomplete with alarms.

Advantages product

ECONOMY SAVING

– Quick return on investment < 1 year
– After installation, the generator require minimal attention and Maintenance

RELIABILITY AND SAFETY OF USE

– Nitrogen produced at low pressure and ambient temperature removes the hazards associated with high pressure cylinders and liquid Dewar’s.
– Nitrogen available on request 24H per day ensuring the walk of the process in a regular and uninterrupted way

COMPACT DESIGN AND FLEXIBLE MODULAR OPTION

– The system demands less floor space
– The modular concept means the generators can be multi banked if required (Master/Slave configuration) Evolutionary System adapting as your business grows and gas requirements change

Characteristics

  • Fully regenerative PSA technology: reduced risk of gas contamination and phthalate free
  • Varying flow rates and purities
  • HMI touch screen technology to display the process in real time, including process variables
  • Oxygen sensor display with alarm
  • Air inlet dewpoint display with alarm
  • Audible alarm display and Visual maintenance indication with history log
  • Analogue connections
  • IP address for remote access via internet connection
  • Quick and easy maintenance: access from front, no rear access required
  • Automatic economy mode: enable to go in standby mode when no N2 is required
  • Specifications

    Models
    TORNADO.
    1110
    2110
    3110
    2130
    3130
    4130
    6130
    8130
    10130
    12130
    Air factor
    N2 FLOW RAT (1) NM3/H VIA O2 PURITY
    99.999% (10 ppm)
    0.9
    1.8
    2.7
    5.1
    7.7
    10.2
    15.3
    20.4
    23.5
    27.2
    6.8
    99.995% (50 ppm)
    1.7
    3.4
    5.1
    7.2
    10.8
    14.4
    21.6
    28.8
    33.1
    38.4
    5.1
    99.99% (100 ppm)
    2.0
    4.0
    6.0
    8.9
    12.6
    16.8
    25.2
    33.6
    38.6
    44.9
    4.6
    99.975% (250 ppm)
    2.5
    5.0
    7.5
    10.0
    15.0
    20.0
    30.0
    40.0
    46.0
    53.3
    3.6
    99.95% (500 ppm)
    3.0
    6.0
    9.0
    11.4
    17.1
    22.8
    34.2
    45.6
    52.4
    60.9
    3.5
    99.9% (0.10%)
    3.6
    7.2
    10.8
    13.2
    19.8
    26.4
    39.6
    52.8
    60.7
    70.5
    3.4
    99.5% (0.50%)
    5.2
    10.4
    15.6
    18.9
    28.4
    37.8
    56.7
    75.6
    86.9
    100.9
    2.8
    99% (1%)
    5.8
    11.6
    17.3
    21.0
    31.5
    42.0
    63.0
    84.0
    96.6
    112.1
    2.7
    98% (2%)
    7.3
    14.5
    21.8
    26.4
    39.6
    52.8
    79.2
    105.6
    121.4
    141.0
    2.4
    97% (3%)
    8.3
    16.7
    25
    30.3
    45.5
    60.6
    90.9
    121.2
    139.4
    161.8
    2.2
    96% (4%)
    9.5
    19.0
    28.5
    34.5
    51.8
    69.0
    103.5
    138.0
    158.7
    184.2
    2.1
    95% (5%)
    10.3
    20.6
    30.9
    37.5
    56.3
    75.0
    112.5
    150.0
    172.5
    200.3
    2.0
    DIMENSIONS
    W x H (mm)
    400 x 1223 (15.7″ x 48″)
    400 x 1823 (15.7″ x 71.7″)
    D (mm)
    605 (23.8″)
    773 (30.4″)
    941 (37″)
    773 (30.4″)
    941 (37″)
    1109 (43.6″)
    1445 (56.8″)
    1781 (70″)
    2117 (83.3″)
    2453 (96.5″)
    SPECIFICATIONS
    Design operating pressure range
    6 – 12 barg (2)
    Design operating temperature range
    5 – 50°C
    Recommended operating temperature
    5 – 25°C
    Maximum inlet particulate
    0.1 micron
    Maximum inlet oil content
    0.01 ppm (4)
    Recommended inlet dewpoint
    -40°C PDP (3)
    Supply voltage
    100 – 240 VAC (50 or 60Hz)
    Power rating
    72W
    PRESSURE CORRECTION FACTORS (5)
    Operating pressure (bar / psig)
    6 / 87
    7 / 101
    8 / 116
    9 / 130
    10 / 145
    11 / 160
    12 / 174
    Correction factor
    0.90
    1.00
    1.10
    1.20
    1.30
    1.40
    1.50
    TEMPERATURE CORRECTION FACTORS (5)
    Inlet temperature (°C / °F)
    5 / 41
    10 / 50
    15 / 59
    20 / 68
    25 / 77
    30 / 86
    35 / 95
    40 / 104
    45 / 113
    50 / 122
    Correction factor
    0.8
    0.9
    0.94
    1.00
    1.00
    0.98
    0.95
    0.90
    0.85
    0.72

    (1) at 7 barg inlet pressure and 20 – 25°C inlet temperature
    (2) 16 barg is available upon request
    (3) recommended for high purity applications
    (4) including oil vapor
    (5) to be used as a rough guide only

    Download documentation

    Having all the necessary information to successfully complete your project is essential, which is why we are providing you with these documents.

    Please feel free to contact us with any questions.

    This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.